In laser science, laser beam quality defines aspects of the beam illumination pattern and the merits of a particular laser beam's propagation and transformation properties (space-bandwidth criterion). By observing and recording the beam pattern, for example, one can infer the spatial mode properties of the beam and whether or not the beam is being clipped by an obstruction; By focusing the laser beam with a lens and measuring the minimum spot size, the number of times diffraction limit or focusing quality can be computed. Anthony E. Siegman was the first to propose the formalism for a laser beam quality factor that could be measured and used to compare different beams, independent of wavelength. The factor is called M2, and it is closely related to the beam parameter product. While the M2 factor does not give detail on the spatial characteristics of the beam, it does indicate how close it is to being a fundamental-mode Gaussian beam. It also determines the smallest spot size for the beam, as well as the beam divergence. M2 can also give an indication of beam distortions due to, for example, power-induced thermal lensing in the laser gain medium, since it will increase. There are some limitations to the M2 parameter as a simple quality metric. It can be difficult to measure accurately, and factors such as background noise can create large errors in M2.〔 Tutorial presentation at the Optical Society of America Annual Meeting, Long Beach, California〕 Beams with power well out in the "tails" of the distribution have M2 much larger than one would expect. In theory, an idealized tophat laser beam has infinite M2, although this is not true of any physically realizable tophat beam. For a pure Bessel beam, one cannot even compute M2. The definition of "quality" also depends on the application. While a high-quality single-mode Gaussian beam (M2 close to unity) is optimum for many applications, for other applications a uniform multimode tophat beam intensity distribution is required. An example is laser surgery. Power-in-the-bucket and Strehl ratio are two other attempts to define beam quality. Both these methods use a Laser beam profiler to measure how much power is delivered to a given area. There is also no simple conversion between M2, power-in-the-bucket, and Strehl ratio. ==M2 definitions== (詳細はequation for the divergence, of a pure Gaussian TEM00 unfocused beam propagating through space is given by :, (2) where ''Θ''0 and ''D''0 are the divergence and waist of a higher mode beam and ''M''2 is greater than 1 and is named the "Beam Propagation Ratio" per the ISO 11146 standard. When a Gaussian laser beam is focused, the focused spot diameter is defined by :. (4) 抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)』 ■ウィキペディアで「Laser beam quality」の詳細全文を読む スポンサード リンク
|